Skip to main content

runReferencing

short summary

This method contains instructions and sequences for the referencing mode. This mode is intended for referencing a machine with relative components, e.g. axes without absoulute position encodeing, torque driven axes (e.g. a press), coupling of master/slave axes. If the node should do nothing, return a 'SUCCESS'. It should run until all devices are referenced or the mode is stopped immedtiately or a stop request is raised (THIS^.modeControl.stopRequest). This method is called automatically by the operation mode handler.

attention: If this method returns the state 'ERROR', the operation mode handler automatically disables the whole machine!

legal notes

| SPDX-FileCopyrightText: © 2024 ekvip automation GmbH <info@ekvip.de> | SPDX-License-Identifier: Apache-2.0 | For details check: Apache-2.0_

.. _Apache-2.0: https://www.apache.org/licenses/LICENSE-2.0

.. </legal notes>

Parameters

NameTypeCommentKind
executeBOOL-input
pauseBOOL-input

Code

Declaration

METHOD runReferencing : CNM_ReturnTypes.SingleExecutionState
VAR_INPUT
execute :BOOL;
pause :BOOL;
END_VAR